{
  "schemaVersion": "1.0",
  "workId": "BRC-2026-W001",
  "generatedAt": "2026-08-13T00:00:00+09:00",
  "purpose": "Record what was actually inspected for each consequential claim. This is not a substitute for the source.",
  "levels": {
    "full_text": "Full article or public primary-text page inspected",
    "abstract_only": "Bibliographic abstract inspected; no full-text claim is implied",
    "page_image_and_transcription": "Public page image/transcription inspected together"
  },
  "items": [
    {
      "claimId": "C01",
      "reference": 1,
      "locator": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5481792/",
      "locationWithinSource": "Results and Table 5",
      "verificationLevel": "full_text",
      "verifiedFacts": ["test–retest correlation 0.609", "expert agreement 74.5%", "kappa 0.487"],
      "limits": "Agreement with expert classification does not establish an external biological criterion."
    },
    {
      "claimId": "C02",
      "reference": 2,
      "locator": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5884007/",
      "locationWithinSource": "Abstract, Results, and consensus tables",
      "verificationLevel": "full_text",
      "verifiedFacts": ["31 experts surveyed", "77.4% prioritized subjective symptoms", "32.2% and 35.5% accepted proposed temperature-difference criteria"],
      "limits": "Expert agreement defines a professional convention, not a mechanism or universal diagnostic gold standard."
    },
    {
      "claimId": "C03",
      "reference": 3,
      "locator": "https://pmc.ncbi.nlm.nih.gov/articles/PMC6500598/",
      "locationWithinSource": "Results and prevalence tables",
      "verificationLevel": "full_text",
      "verifiedFacts": ["34.2% reported cold hypersensitivity at one or more measured sites"],
      "limits": "Cross-sectional self-report prevalence does not identify cause."
    },
    {
      "claimId": "C04",
      "reference": 4,
      "locator": "https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART003307068",
      "locationWithinSource": "Publisher bibliographic record and abstract",
      "verificationLevel": "abstract_only",
      "verifiedFacts": ["109 studies reported: 36 Korean and 73 Japanese", "authors state that unified diagnostic criteria remain needed"],
      "limits": "The search strategy, individual inclusions, and risk of bias were not re-audited from full text."
    },
    {
      "claimId": "C05",
      "reference": 14,
      "locator": "https://pubmed.ncbi.nlm.nih.gov/20497044/",
      "locationWithinSource": "Abstract",
      "verificationLevel": "abstract_only",
      "verifiedFacts": ["objective and subjective hot-flash measures were compared within the same study"],
      "limits": "Used as evidence that reporting and physiological event detection can diverge, not as a model of all localized heat."
    },
    {
      "claimId": "C06",
      "reference": 16,
      "locator": "https://pmc.ncbi.nlm.nih.gov/articles/PMC6001804/",
      "locationWithinSource": "Methods, Results, and discussion of cold challenge and rewarming",
      "verificationLevel": "full_text",
      "verifiedFacts": ["dynamic rewarming after cold challenge was assessed", "repeatability and discriminatory performance were evaluated"],
      "limits": "Raynaud phenomenon is a vascular natural experiment, not an explanation for every complaint of cold hands."
    },
    {
      "claimId": "C07",
      "reference": 17,
      "locator": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5207547/",
      "locationWithinSource": "Results",
      "verificationLevel": "full_text",
      "verifiedFacts": ["296 CRPS patients were analyzed", "44.3% had an absolute side-to-side temperature difference of 1°C or less"],
      "limits": "This challenges one-time temperature thresholds; it does not invalidate thermography for every protocol."
    },
    {
      "claimId": "C08",
      "reference": 24,
      "locator": "https://app.mediclassics.kr/books/%EB%8F%99%EC%9D%98%EB%B3%B4%EA%B0%90/pages/1483",
      "locationWithinSource": "Public KIOM page 1483, table-of-contents sequence",
      "verificationLevel": "page_image_and_transcription",
      "verifiedFacts": ["separate headings preserve depth, region, day/night, triple-burner distribution, and five-centre heat"],
      "limits": "Editorial structure is historical evidence, not validation of modern physiology."
    },
    {
      "claimId": "C09",
      "reference": 25,
      "locator": "https://app.mediclassics.kr/books/%EB%8F%99%EC%9D%98%EB%B3%B4%EA%B0%90/pages/752",
      "locationWithinSource": "Public KIOM page 752, 背熱",
      "verificationLevel": "page_image_and_transcription",
      "verifiedFacts": ["the entry reads 背熱屬肺. 肺居上焦, 故熱應於背", "the source marker points to Yixue Rumen"],
      "limits": "Edition genealogy and the Yixue Rumen source passage were not compared in this version."
    },
    {
      "claimId": "C10",
      "reference": 26,
      "locator": "https://app.mediclassics.kr/books/%EB%8F%99%EC%9D%98%EB%B3%B4%EA%B0%90/pages/1379",
      "locationWithinSource": "Public KIOM page 1379, 厥與四逆不同",
      "verificationLevel": "page_image_and_transcription",
      "verifiedFacts": ["the entry distinguishes generalized limb reversal from hand-and-foot counterflow"],
      "limits": "The passage supplies a spatial distinction, not a direct equivalence with current symptom phenotypes."
    }
  ],
  "unresolved": [
    "Complete full-text inspection of the 2026 Korean–Japanese scoping review",
    "Edition comparison and source-lineage audit for the Yixue Rumen attribution",
    "Exhaustive Chinese-language database and citation-network searching",
    "Independent replication of every bibliographic field"
  ]
}
